[Logo Image] BT TECHNOLOGY INC GEOSYNTHETIC 2001a

MELT FLOW INDEX EQUIPMENT

[Item Image] MELT FLOW SYSTEMS USED TO
DETERMINE THE FLOW
CHARACTERISTICS OF VARIOUS
POLYMERS
MELT FLOW INDEX EQUIPMENT
Melt Flow Index Testers and Accessories

BT Technology Inc. has two melt flow index models available as well as a
variety of options to support them.

AD-S-BA-000 Melt Indexer (Method A)
AD-S-BA-500 Melt Indexer (Method A & B)

Both devices meet ASTM D1238 and D 3364

In our experience Method A is the most accepted procedure for most polymers
used in geosynthetics.

Test Weights For Melt Flow Testing
(* add 100g piston weight to equal ASTM weight requirement)

AC-C-AA-225 225g
AC-C-AA-900 900g
AC-C-AA-950 950g
AC-C-AA-110 1,100g
AC-C-AA-206 2,060g
AC-C-AA-370 3,700g
AC-C-AA-490 4,900g
AC-C-AA-990 9,900g
AC-C-AA-124 12,400g
AC-C-AA-199 19,900g
AC-C-AA-215 21,500g

"E" Melt "F"Melt and "P" Melt are most common
An additional charge should be added to purchase a set of replacement parts and
some consumable cleaning supplies.
AD-S-BA-000 Melt Indexer (Method A)


Indexer Base Features
-Base materials constructed of stainless steel and aluminum
-Heat Chamber alloy tool steel , vacuum hardened
-Stainless steel piston with removable hardened tool steel tip
-Stainless steel packing and clean out tool kit
-Stainless steel mica band heater with dual zone and non-asbestos insulation with
a
stainless steel shell around the heat chamber for operating ranges up to 425 C
-ASTM D 1238 Tungsten carbide die and go / no go gage
-Heavy duty power supply
-Digital read out of temperature to +/- 0.1 C
-Four wire 100 Ohm platinum RTD for sensing and controlling temperature
-Line cord with power filter, fuse and on-off switch

Indexer Electronic Package

-Thirty-two bit Micro Processor Temperature control (+ / - 0.1 C) and display
system
-Digital temperature input system
-Digital display w/membrane touch type panel for all program inputs
-Temperature are shown on instrument front
-System auto checks RTD for open shorts
-Over temperature alarm and cut off
-Five program memory


AD-S-BA-500 Melt Indexer (Method A & B)

This device has all the features of AD-S-BA-000 plus the following.

-Electronic eye for measuring Method B flag
-Flag set consisting of three flag tapes one @ 1-1/4" one @ 2-1/4" and one @ 1"
-Multiple flags can be run in Method B or multiple cuts taken with Method A
-Twenty program memory
-Can be fit with a pneumatic lift option for heavier weights

AD-C-BA-500 Pneumatic Test Weight Lift and Control System











PRICE LIST - 80101
LMI 4000
MODELS AD-S-D4001, AD-S-D4002, AD-S-D4003, AD-S-D4004
(ASTM D1238/D3364/ISO 1133)

MODEL AD-S-D4001 (METHOD A ONLY)

ITEM CODE DESCRIPTION
1.00 Model AD-S-D4001 in accordance with the following specifications:
1.01 Instrument base material constructed of stainless steel and
aluminum.
1.02 Heat chamber alloy tool steel vacuum hardened.
1.03 Stainless steel piston with removable hardened tool steel tip.
1.04 Stainless steel packing and cleanout tools.
1.05 Stainless steel mica band heater dual zone and /non-asbestos
insulation
with stainless steel shell around heat chamber for operation up to 425*C.
1.06 ASTM D1238 tungsten carbide die and go/no-go gage.
1.07 Heavy duty power supply.
1.08 Digital readout of temperature to ±0.1 *C.
1.09 Four wire 100 OHM platinum RTD for sensing and controlling
temperature.
1.10 Line cord with filter, fuse, and on-off switch.
1.11 Operating instructions.

2 2.00 LMI 4000 electronic package housed in base with the following:
2.01 Thirty two bit Micro-Processor temperature control (±0.1 *C.) and
display system.
2.02 Digital temperature input system.
2.03 Digital display w/membrane-type touch panel for all program inputs.
2.04 Temperature/flow rate are computed and shown on instrument front.
2.05 System automatically checks RTD for open or short.
2.06 Over-temperature alarm and cut off.
2.07 Memory battery back up for entire system.
2.08 Five Program Memory.
******* .
3 3.00 PART WEIGHT
#AD-C-0051-49 225 g
#AD-C-0051-50 1,100 g For a listing of required weights
#AD-C-0051-51 2,060 g for various materials, see
# AD-C-0051-52 3,700 g Technical Bulletin #1001 or refer
to ASTM D1238
#AD-C-2054-24 4,900 g Test Method

MODEL AD-S-D4001: (Wired for 110 VAC, 60Hz)
MODEL AD-S-D4001 HV (Wired for 220 VAC, 50Hz)
The Model AD-S-D4001 is recommended where occasional melt index testing is
required.

MODEL AD-S-D4002

ITEM CODE DESCRIPTION
1 1.00 Model AD-S-D4002 in accordance with Model AD-S-D4001, plus the
following:
1.01 Electronic Eye sensing system for measuring Method B flag travel
time.
1.02 Flag set consisting of three tapes: one tape with 1-¼" flag; one tape
with
2 -¼" flag; and one tape with 1-1" flag.
1.03 Multiple flags can be run in Method B or multiple cuts taken in
Method A.
1.04 Choice of (1) stainless steel weight 225, 1100, 2060, 3700, 4900 gm
(Please Specify)
1.05 Lowest Cost Model Pneumatic Lift Option is available (see Option
AD-C-D4056)
1.06 Twenty program memory. Program selection automatically loads all
test
parameters, including orifice dimensions, material ID, temperatures,
etc.
1.07 Prewired for expansion to higher model at later date.

MODEL AD-S-D4002: (Wired for 110 VAC, 60Hz)
MODEL AD-S-D4002HV (Wired for 220 VAC, 50Hz)
The addition of Method B testing in the Model AD-S-D4002 frees operators for
additional duties during routine operation. The expanded weight set allows running
many common materials including polyethylene, polypropylene, polycarbonate, etc.
(see KAYENESS Technical Bulletin #1001 for a more complete listing). The model
AD-S-D4002 has the features of the AD-S-D4001 plus twenty program memory and is
prewired for the Pneumatic Lift Option (AD-C-D4056) and expansion to higher models
in the LMI 4000 series. The twenty program memory is perfect for operations with
more than one type or grade of polymer. The expansion capability is also included in
this model in case more varied testing is expected or the pneumatic lift might be
necessary at a later date.

MODEL D4003

ITEM CODE DESCRIPTION

1 1.00 Model AD-S-D4003 in accordance with Model AD-S-D4002, plus the
following:
1.01 Full 60 program memory. Program selection automatically loads all
test parameters,
including orifice dimensions, material ID, temperatures, etc.
1.02 Computes shear stress, shear rate, and viscosity in English, metric,
or S.I. units.
1.03 Average, standard deviation, and coefficient of variance are
calculated for viscosity,
shear rate and stress, and flow rates for test series.
1.04 Flow rate ratio can be done in one run with all data from each
individual run being
printed.
1.05 Enter and record operator code, sample and material I.D.
1.06 Q.C. limits may be entered and pass, high or low will be calculated
and displayed on the
print out
1.07 Includes intrinsic viscosity (IV) correlation of PET capability.
1.08 Flag set consisting of 7 tapes: one tape with 1 - 1" flag; one tape
with 2 - ½" flags; one
tape with 3 - 1/8" flags; one tape with 1 - 1" and 1 -¼" flags; one tape
with 3 - ¼" flags;
one tape with 2 -¼" flags; and one tape with 1 - ¼" flag. (This set is
standard for the
AD-S-D4003 model and the AD-S-D4004 model.)

MODEL AD-S-D4003: (Wired for 110 VAC, 60 Hz)
MODEL AD-S-D4003HV (Wired for 220 VAC, 50Hz)

The Model AD-S-D4003 is preferred by most users because of its programming
flexibility (sixty programs) and the notebook form print-out. The print-out from the
AD-S-D4003 shows viscosity, shear rate, and shear stress, in addition to flow rate.
Additionally, statistical quality or process control limits can be monitored. Flow rate
ratio or multiple flags with a single weight can be done on one Method B test.
Alternatively, multiple sample cuts can be taken in Method A testing. Note: A printer
is required to fully utilize the Model AD-S-D4003 enhanced electronic package.
(See Option AD-C-GP7984)

MODEL D4004

ITEM CODE DESCRIPTION
1 1.00 Model AD-S-D4004 in accordance with Model AD-S-D4003, plus the
following:

1.01 Special circuit board with memory and RS232 serial port for
interfacing with
Personal computers can also interface with other computers,
conduct multiplexing, etc.
1.02 Includes (1) copy of MIWORKS for WINDOWS Software.

Model AD-S-D4004: (Wired for 110VAC, 60Hz)
Model AD-S-D4004HV (Wired for 220VAC, 50Hz)


Our most advanced melt indexer is the Model AD-S-D4004. It has the features of the
Model AD-S-D4003, plus memory and RS232 serial ports for interfacing with the
personal computers. The Multiplexing option allows a single computer to collect data
from eight melt indexers (or more in units of eight) via a single personal computer.
The Model AD-S-D4004 is used in situations requiring computer laboratory
management systems or electronic database systems. Note: A printer is required to
fully utilize the Model AD-S-D4004 enhanced electronic package.
(See Option AD-C-GP7984)

Training: One-day training at the factory is included with all our instruments. We
discuss maintenance and operation of this equipment. Training is available
at customer's location for a nominal charge.

Warranty: Every instrument comes with a one-year warranty against manufacturing
defects.
Prices valid 60 days from receipt of Formal Quotation.
For purchase and/or delivery information, please contact Order Department. Minimum
Order $50.00.



________________________________________________











PRICE LIST - 80105 LMI 4000 MELT INDEXER OPTIONS

ITEM CODE DESCRIPTION
1 1.00 OPTION AD-C-D4056
Pneumatic Lift System for LMI 4000 KAYENESS Melt Indexers in
accordance with the
following specifications (Available only on Models AD-S-D4002,
AD-S-D4003,
AD-S-D4004)
1.01 Pneumatic cylinder capable of lifting 25,000 grams of weight.
1.02 Large air cylinder with weight support system and safety pin.
1.03 Manual raise/lower valve, with lock valve to lock weight and cylinder
in any location.
1.04 Aluminum mounting system, w/large mounting base plate.
1.05 Automatic Valve Lowering System with pneumatic valve and
P.C.Board for automatic or
manual lowering.

This system allows heavy weights to be lowered manually or automatically during
testing. The pneumatic lift options permits flow rate ratio testing to be done
automatically during Method B runs. For safety reasons, the Pneumatic Lift System
is recommended for heavy weights (over 10 kg).

2 2.00 OPTION AD-C-D7057
Small weight insert including plastic tube for use with Pneumatic Lift
System AD-C-D7056, AD-C-D4056 and small weights (1100, 2060,
3700 gm).

3 3.00 OPTION AD-C-D4058
Pneumatic Mini-Lift system for KAYENESS LMI 4000 Melt Indexers
for raising and
lowering up to 3700 gm weight and piston rod assembly. (Weight
must
be manually placed on top of piston rod assembly.)

4 4.00 Additional weights for LMI 4000 Melt Indexers. (Remember piston
weights 100g.)

PART # WT
AD-C-0051-49 225 G
AD-C-2054-22 900 G
AD-C-2054-23 950 G
AD-C-0051-50 1,100 G
AD-C-0051-51 2,060 G
AD-C-0051-52 3,700 G
AD-C-2054-24 4,900 G
AD-C-2054-25 9,900 G
AD-C-2054-26 12,400 G
AD-C-2054-28 19,900 G
AD-C-2054-29 21,500 G
AD-C-2054-27* 19,440 G
AD-C-2054-27S* 19,440G

* Adder weight for flow rate ratio; added to 2160 g for 21.6 kg.

For a listing of required weights for various materials, see KAYENESS Technical
Bulletin #1001

5 5.00 AD-C-D4057
Alloy barrel for testing PVC and other corrosive materials, installed in
place of standard
tool steel barrel and includes Hastelloy piston tip (P/N
AD-C-0051-41H)


6 6.00 AD-C-4050P
Mini Printer Option for use with Model AD-S-D4002 includes table
top impact printer and cable, wall mount transformer 120 VAC, 60HZ

AD-C-7050P HANDI-PAK (4) rolls paper/(2) ribbon cartridges

7 7.00 AD-C-GP8000
KAYENESS Data Processing System - Pentium 266 MMX or
better, 32 MB RAM, 1.44M 3 ½" floppy disk drive, 4 GB or larger Hard disk drive, CD
ROM (2) serial, (1) parallel, (1) mouse ports, Super VGA color monitor, keyboard and
mouse/windows 95 installed. .

The Data Processing System acts as an R&D or QC electronic database. This
system is recommended for those customers who plan to use statistical process and
quality control techniques extensively. The software package includes control
charting with ranges and standard deviations.

8 8.00 AD-C-MULTIPLEX
KAYENESS Multiplexing Hardware for connecting up to eight Model
AD-S-D4004 units
to a single computer. Consists of: RS232 scanner with four
channels and connecting
cables. Also contains software program for controlling and scanning
multiplexer, naming
files, and temporarily storing date.(For use with Model AD-S-D4004
only.)
NOTE: Customer must provide dimentional drawing indicating
location of melt indexers
in relation to computer so that proper cables can be supplied.

The Multiplexing Option allows multiple LMI 4000 melt indexers to be connected to a
single personal computer. It is used only in conjunction with the Model AD-S-D4004.


9 9.00 AD-C-D2044
Electronic eye calibrator for determining the exact dimension at
which eye responds.
Platform with: mounting system, dial micrometer, and fine thread
adjustment with tape
mounting adapter.

The calibrator is used to adjust the sensitivity of the electronic eye. We recommends
this instrument for part of routine calibration of the melt indexer.

10 10.00 AD-C-D4059
Digital encoder for performing Method B testing per ASTM D1238
includes high
resolution digital encoder to measure piston rod position and speed
of descent,
up to 15 measurements per barrel charge, permits melt index values
in real-time,
automatic or manual selection of flag length includes piston
assembly (7051-72)
NOTE: Electronic eye not included when purchased with new
instrument.
Electronic eye is disabled when retrofitting to existing
instrument.


10.01 AD-C-7051-59
Ditigal encoder calibrator for adjusting the sensitivity of digital
encoder includes
mounting system and dial micrometer.

11 11.00 AD-C-GP7984
Cannon Bubble Jet printer with connecting cable (paracable). A
printer is required with
the Models AD-S-D4003 and AD-S-D4004 to fully utilize the
advanced electronics.

12 12.00 AD-C-0051-83
TEFLON PTFE-tipped high melt flow plug to retain high flow
polymers in barrel during
preheat.

For extremely high flow polymers (over 10 g/10 min), the High Melt Flow Plug is
recommended. Without
this plug, high flow polymers have a tendency to drain out of the barrel during the
pre-heat cycle.

13 13.00 AD-C-7051-90
Digital Electronic Scale(.01 gm resolution),capacity: 0.01 x 120 gm,
full digital
calibration,overload protection,115VAC (other voltages
available-consult factory)

A low cost, general purpose, compact balance used for weighing
samples to
determine melt flow number. Not recommended for fractional melt
materials.

14 14.00 RECOMMENDED MELT INDEXER SPARE PARTS

ITEM PART NO. DESCRIPTION
1 AD-C-0051-30 Piston assembly
2 AD-C-0051-41 Piston Tip
3 AD-C-0051-80 Fill Funnel
4 AD-C-0051-46 Orifice (Tungs Carbide)
5 AD-C-0051-46SS Orifice (Stainless Stl)
6 AD-C-0051-48 Bronze Brushes
7 AD-C-0051-53 Cut-Off Tool
8 AD-C-7051-31C Tapes with ¼" Flag
9 AD-C-7051-31E Tapes with 1" Flag
10 AD-C-GP0300 Pyrex Beaker
11 AD-C-GP0310 S.S. Orifice Brushes
12 AD-C-GP1751P2 Platinum RTD

15 15.00 AD-C-D4000 K MI KIT PACKAGE
Includes above parts (excluding #5) at a 10% discount and contains
all consumables and
sufficient normal spare parts.
(*)Kit Package substituting Stainless Steel Orifice for Tungsten
Carbide Orifice.


16 16.00 AD-C-8052-97K Barrel Bore Power Cleaning Kit
Includes rechargeable power drill, battery charger , carrying case and
(1) special cleaning tool, 110 VAC.
AD-C-8052-98S Bore Cleaning tip- spare set of (3
AD-C-8052-99S Bore Cleaning rod- spare set of (3)

17 17.00 AD-C-GRAN
Mini-Granulator, High Speed motor, 4" x 3" feed opening, (2) rotor ,
(1) stator
carbon steel knives, 5.5 MM diameter hole interchangeable sieve,
easy cleaning
cast iron cutting chamber/feed hopper with safety interlock. Free
standing angle
base, 220 VAC, 50 HZ

ACCESSORIES
AD-C-GRAN-03 Granulator spare parts kit includes (2) rotor, (1)
stator carbon steel



knives, mounting screws and shims
AD-C-GRAN-04 Sieve, 4MM diameter holes
AD-C-GRAN-05 Sieve, 5.5MM diameter holes
AD-C-GRAN-08 Sieve, 8MM diameter holes
AD-C-GRAN-01 Granulator stand, heavy duty steel construction
AD-C-GRAN-02 Granulator collection bin, for use w/AD-C-GRAN-01
stand


Prices Valid 60 days from receipt of Formal Quotation
.
Training: One-day training at our factory is included with all our instruments. We
discuss maintenance and operation of this equipment. Training is available
at customer's location for a nominal charge.

Warranty:Every instrument comes with a one-year warranty against manufacturing
defects.
For purchase and/or delivery information, please contact Order Department.

Minimum order $50.00

BT TECHNOLOGY INC.

320 N. Railroad St.
P.O. BOX 49
320 North Railroad Street
RUSHVILLE, IL. 62681
Telephone: (217) 322-3768
Fax: (217) 322-3767